Type R4D355-RM04-01
Motor M4D094-EA
Phase 3~ 3~ 3~ 3~
Nominal voltage VAC 230 230 400 400
Wiring Δ Δ Y Y
Frequency Hz 50 60 50 60
Method of obtaining data ml ml ml ml
Valid for approval/standard CE CE CE CE
Speed (rpm) min-1 1370 1530 1370 1530
Power consumption W 270 400 270 400
Current draw A 1.06 1.22 0.61 0.70
Min. back pressure Pa 0 0 0 0
Min. back pressure inH2O 0 0 0 0
Min. ambient temperature °C -40 -40 -40 -40
Max. ambient temperature °C 60 60 60 60
Starting current A 3.65 3.25 2.1 1.86
Mass 5.6 kg
Fan size 355 mm
Impeller material PP plastic
Number of blades 6
Direction of rotation Clockwise, viewed toward rotor
Degree of protection IP54; installation- and position-dependent as per EN 60034-1
Insulation class “F”
Moisture (F) / Environmental (H)
protection class F4-1
Max. permitted ambient temp.
for motor (transport/storage) + 80 °C
Min. permitted ambient temp. for
motor (transport/storage) – 40 °C
Installation position Any
Condensation drainage holes None
Mode S1
Motor bearing Ball bearing
Touch current according to IEC
60990 (measuring circuit Fig. 4,
TN system) <= 3.5 mA
Motor protection Thermal overload protector (TOP) with basic insulation
With cable Variable
Protection class I (with customer connection of protective earth)
Conformity with standards EN 60034-1 (2004); CE