Type D2E146-AP50-68
Motor M2E068-EC
Phase 1~ 1~
Nominal voltage VAC 230 230
Frequency Hz 50 60
Method of obtaining data ml ml
Valid for approval/standard CE CE
Speed (rpm) min-1 2600 2700
Power consumption W 250 340
Current draw A 1.1 1.5
Capacitor μF 8 8
Capacitor voltage VDB 400 400
Capacitor standard S2 (CE) S2 (CE)
Min. back pressure Pa 420 455
Min. back pressure in. wg 1.69 1.83
Min. ambient temperature °C -25 -25
Max. ambient temperature °C 65 40
Mass 4.28 kg
Size 146 mm
Motor size 68
Rotor surface Unpainted
Impeller material Sheet steel, galvanized
Housing material Sheet steel, galvanized
Motor suspension Motor mounted with brackets on one side
Direction of rotation Counterclockwise, viewed toward rotor
Degree of protection IP44; installation- and position-dependent
Insulation class «F»
Moisture (F) / Environmental (H)
protection class
H0 – dry environment
Max. permitted ambient temp.
for motor (transport/storage) + 80 °C
Min. permitted ambient temp. for
motor (transport/storage) – 40 °C
Installation position Any
Condensation drainage holes None
Mode S1
Motor bearing Ball bearing