AxiACi120

Categoría:

Type AxiACi120
Fan type Axial
Rotating direction looking at rotor Clockwise
Airflow direction Air outlet over struts
Bearing system Ball bearing
Mounting position – shaft Any
Width 120,0 mm
Height 120,0 mm
Depth 38,0 mm
Diameter 0,0 mm
Mass 0,275 kg
Housing material Plastic
Impeller material Plastic
Max. torque when mounted across both mounting
flanges
Screw size
Wire outlet corner: 50 Ncm
Remaining corners: 80 Ncm
ISO 4762 – M4 degreased, without an additional
brace and without washer
Rotor protrusion max. 0,6 mm
Electrical connection Cable
Lead wire length L = 310 mm
Tolerance +- 20 mm
Wire size (AWG) 20
Voltage range 100V 240V
Tolerance U -10,0% 1,0%
Nominal voltage UN 115 V 230 V
Power consumption ∆p = 0 P 1,7 W
Tolerance +- 20 %
Current consumption ∆p = 0 IRMS 29 mA 26 mA 14 mA 14 mA
Tolerance +- 20 % +- 20 % +- 20 % +- 20 %
Speed ∆p = 0 n 1.850 1/min
Tolerance +- 10 %
Electronic function Speed-Controlled
Locked rotor protection Auto restart
Clock signal at locked rotor t3/t4 typical: 6,3 s / 10 s
Max. free-air flow (∆p = 0 / = max.) 96 m3/h
Max. static pressure (∆p = max. / =0) 47 Pa
Min. permitted ambient temperature TU min. -40 °C
Max. permitted ambient temperature TU max. 75 °C
Min. permitted storage temperature TL min. -40 °C
Max. permitted storage temperature TL max. 80 °C

Scroll al inicio