Type D4D180-CB01-02
Motor M4D068-GA
Phase 3~ 3~ 3~ 3~
Nominal voltage VAC 230 230 400 400
Wiring Δ Δ Y Y
Frequency Hz 50 60 50 60
Method of obtaining data fa fa fa fa
Valid for approval/standard CE CE CE CE
Speed (rpm) min-1 1050 1030 1050 1030
Power consumption W 290 360 290 360
Current draw A 0.92 1.04 0.53 0.6
Min. back pressure Pa 0 0 0 0
Min. back pressure inH2O 0 0 0 0
Min. ambient temperature °C -25 -25 -25 -25
Max. ambient temperature °C 55 30 55 30
Mass 9.5 kg
Fan size 180 mm
Rotor surface Unpainted
Impeller material Sheet steel, hot-dip galvanized
Housing material Sheet steel, hot-dip galvanized
Motor suspension Motor vibration-damped on both sides
Direction of rotation Counterclockwise, viewed toward rotor
Degree of protection IP54
Insulation class “B”
Moisture (F) / Environmental (H) protection class F3-1
Max. permitted ambient temp.
for motor (transport/storage) + 80 °C
Min. permitted ambient temp. for
motor (transport/storage) – 40 °C
Installation position Any
Condensation drainage holes None
Mode S1
Motor bearing Ball bearing
Weight | 10 kg |
---|---|
Brand |