Type G3G200-GN18-01
Motor M3G084-DF
Phase 1~
Nominal voltage VAC 230
Nominal voltage range VAC 208 .. 240
Frequency Hz 50/60
Type of data definition ml
Speed min-1 5700
Power input W 750
Current draw A 3.6 (208V)
Min. ambient temperature °C -20
Max. ambient temperature °C 60
Min. temp. of flow medium °C 0
Max. temp. of flow medium °C 60
Mass 9.2 kg
Size 200 mm
Surface of rotor Coated in black
Material of protective cover Polyflam RPP 374-ND CS1
(UL 97-V0)
Material of impeller Aluminium sheet
Housing material Die-cast aluminium
Number of blades 7
Direction of rotation Clockwise, seen on rotor
Type of protection IP 20
Insulation class “B”
Max. permissible ambient motor
temp. (transp./ storage) +80 °C
Min. permissible ambient motor
temp. (transp./storage) -40 °C
Mounting position Any
Condensate discharge holes Rotor-side
Operation mode S1
Motor bearing Ball bearing