S4D450-AN14-02

CONTACT

Type S4D450-AN14-02
Motor M4D094-FA
Phase 3~ 3~
Nominal voltage VAC 400 400
Wiring Δ Y
Frequency Hz 50 50
Method of obtaining data ml ml
Valid for approval/standard CE CE
Speed (rpm) min-1 1330 1040
Power consumption W 460 310
Current draw A 0.95 0.52
Max. back pressure Pa 130 78
Max. back pressure inH2O 0.52 0.31
Min. ambient temperature °C -25 -25
Max. ambient temperature °C 65 65
Starting current A 3.3 1.1
Mass 8.5 kg
Fan size 450 mm
Rotor surface Painted black
Terminal box material ABS plastic
Blade material PP plastic
Guard grille material Steel, coated with black plastic (RAL 9005)
Number of blades 5
Airflow direction “A”
Direction of rotation Clockwise, viewed toward rotor
Degree of protection IP54
Insulation class “F”
Moisture (F) / Environmental (H)
protection class F4-1
Ambient temperature note Occasional start-up between -40°C and -25°C is permissible.
For continuous operation at temperatures below -25°C (e.g. refrigeration
applications) we recommend our fan design with special low-temperature bearings.
Max. permitted ambient temp.
for motor (transport/storage) + 80 °C
Min. permitted ambient temp. for
motor (transport/storage) – 40 °C
Installation position Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes On rotor side
Mode S1
Motor bearing Ball bearing

Scroll to Top